Differential Pressure Bypass Balance Valve, DN65, PN16, CF8
Discover the high-performance 800X differential pressure by-pass balancing valve manufactured by a trusted factory. This valve is designed with DN65 size and PN16 pressure rating, conforming to ASTM A351 CF8 standards. It features a 2-1/2 inch size and Class 150 LB rating, with SS 304 trim for durability. The valve is equipped with RF flanged ends for easy installation. Upgrade your system with this reliable and efficient balancing valve.
Categories
- Control Valves
Tags
- Flanged Control Valve , RF Control Valve , Class 150 LB Control Valve
Detail Information
Product: 800X differential pressure bypass balance valve
Size: DN65
Pressure: PN16
Body Material: ASTM A351 CF8
Trim: SS 304
Performance standard:
Quality assurance: IS0 9001
Design: CJ/T 167, CJ/T 219
Structure Length: CJ/T 167, GB/T 12221
Test Standard: GB/T 13927
Connection: RF Flange
The 800X differential pressure bypass balance valve is composed of a main valve, a differential pressure control pilot valve, a needle valve, a ball valve, a micro filter and a pressure gauge to form a hydraulic control takeover system. Through the specially designed pilot valve control room, the pressure change signal is compared. The main valve opening signal is output. The main valve opening is controlled, and the pressure difference between the inlet and outlet of the main valve is controlled at the set value. This product uses hydraulic self-control, does not require other devices and energy, and is easy to maintain. It is widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.
Size: DN65
Pressure: PN16
Body Material: ASTM A351 CF8
Trim: SS 304
Performance standard:
Quality assurance: IS0 9001
Design: CJ/T 167, CJ/T 219
Structure Length: CJ/T 167, GB/T 12221
Test Standard: GB/T 13927
Connection: RF Flange
The 800X differential pressure bypass balance valve is composed of a main valve, a differential pressure control pilot valve, a needle valve, a ball valve, a micro filter and a pressure gauge to form a hydraulic control takeover system. Through the specially designed pilot valve control room, the pressure change signal is compared. The main valve opening signal is output. The main valve opening is controlled, and the pressure difference between the inlet and outlet of the main valve is controlled at the set value. This product uses hydraulic self-control, does not require other devices and energy, and is easy to maintain. It is widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.
Next: ASTM A351 CF8 Hydraulic Electric Control Valve, DN65, PN16