ASTM A351 CF8 Water Pump Control Valve, DN300, 12 Inch, PN16
Get superior control valves made from ASTM A351 CF8 stainless steel from a trusted supplier. Our valves are specifically designed for DN300 (12 inch) applications with PN16 pressure rating and Class 150 LB compatibility. Featuring SS 304 trim and RF flange, these valves ensure efficient water pump operation. Enjoy hassle-free maintenance and outstanding performance with our high-quality control valves. Order now for reliable and durable solutions.
Categories
- Control Valves
Tags
- ASTM A351 CF8 Control Valve , DN300 Check Valve , 12 Inch Check Valve
Detail Information
Product: Water Pump Control Valve
Size: DN300
Pressure: PN16
Body: ASTM A351 CF8
Trim: SS 304
Performance standard:
Quality assurance: IS0 9001
Design: CJ/T 167, CJ/T 219
Structure Length: CJ/T 167, GB/T 12221
Test Standard: GB/T 13927
Flange standard: GB/T 17241.6, GB/T 9124.1, GB/T 9113
Connection: RF Flange
700X water pump control valve consists of a main valve, solenoid pilot valve, needle valve, ball valve, check valve, travel switch, micro filter and pressure gauge to form a hydraulic control takeover system. When the pump needs to stop working, the main valves are closed by 90% by the inlet pressure, and then the pump stops running. The remaining 10% is closed by the return water. Prevents the occurrence of water hammer. When the water pump stops working, the solenoid pilot valve closes first, the main valve control room stops draining water, the pressure in the control room rises, and the main valve starts to close. Energy saving, easy maintenance, stable pump shutdown, widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.
Size: DN300
Pressure: PN16
Body: ASTM A351 CF8
Trim: SS 304
Performance standard:
Quality assurance: IS0 9001
Design: CJ/T 167, CJ/T 219
Structure Length: CJ/T 167, GB/T 12221
Test Standard: GB/T 13927
Flange standard: GB/T 17241.6, GB/T 9124.1, GB/T 9113
Connection: RF Flange
700X water pump control valve consists of a main valve, solenoid pilot valve, needle valve, ball valve, check valve, travel switch, micro filter and pressure gauge to form a hydraulic control takeover system. When the pump needs to stop working, the main valves are closed by 90% by the inlet pressure, and then the pump stops running. The remaining 10% is closed by the return water. Prevents the occurrence of water hammer. When the water pump stops working, the solenoid pilot valve closes first, the main valve control room stops draining water, the pressure in the control room rises, and the main valve starts to close. Energy saving, easy maintenance, stable pump shutdown, widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.
Next: ASTM A351 CF8 Hydraulic Electric Control Valve, DN500, PN16
Previous: ASTM A351 CF8 Pressure Sustaining Valve, DN200, PN25, RF